Bear 150 Variable Frequency Drive – 150 HP / 110 kW / 189 Amp
The Bear 150 VFD variable frequency drive with a 189 Amp can be used with any standard AC motor, and the IP65 protection rating Bear 150 VFD could be installed on the motor directly, with no need for extra PLC, relay, contactors, and control box. The built-in application software makes it the most convenient driver for debugging, programming, and operation.
The professional control and protection function for the pump and motor, the soft start and stop, incredibly improve the service life of the pump, motor, and pipe. All these features make this compact and easy-to-use drive reliable and energy-saving up to 70%, suitable for almost any application.
The Bear 150 is part of the Bear Variable Frequency Drive Series which offers a variety of sizes and powers.

Get Pricing
Features
- Efficient Transformation
- Efficient Configuration
- Efficient Energy Use
- Economy
- Easy to debug and operate
- Easy to install
Variable Frequency Drive Technical Specs
Model | Bear 150 VFD |
Rated Data | |
Input | |
Number of phases | AC 3PH |
Rated power (KW) | 110 |
Voltage range(V) | 400~500 |
Frequency range HZ) | 47~63 |
Rated input | |
current(A) | 195 |
Power factor | 95% |
Output | |
Number of phases | AC 3PH |
Rated Power (KW) | 110 |
Voltage range(V) | 0~500 |
Frequency range (Hz) | 0~600 |
Rated output | |
current(A) | 189 |
Power factor | 0.95 |
Input & Output options | 1AC 220V±15%, |
3AC 220V±15 %, 3AC 380V±15%, |
Horsepower | 150 HP |
General tech. specifications | |
Power Factor | 95% |
Control mode | V/F control, non-PG vector control (SVC) PG vector control (FVC) |
Efficiency | 98% |
Sound pressure level(1m) | 50dB |
Power loss (KW) | 2.2 |
Speed adjusting range | 1:100(SVC) 1:1000(FVC) |
Speed control accuracy | ±0.5%(SVC) ±0. 02%(FVC) |
V/F control | V/F separation number |
Start torque | 0.5Hz/100 % |
Torque boost | Automatic torque boost; manual torque boost 0.1~30% |
DC brake | Supports starting and stopping DC brake |
Traverse control | Traverse controls l function: multiple triangular pulse frequency control |
Fixed length control | Setting length control |
Timing control | Setting time range:0~6500min |
Overload capacity | 120% rated current 60s, 150% rated current 3s |
Output terminals | 1. 4 relay outputs |
2. 1 analog output: voltage output |
VFD Rental
DAE Pumps offers sales, turnkey rentals, and dredging solutions to clients worldwide. We have over 30 years of experience completing the most challenging dredging projects worldwide. Monthly rentals for dredging, dewatering, self-prime needs, and special diver dredge projects.
Why Rent?
- Try out VFDs before purchase
- Great for short-term projects 2-12 months
- Rent-to-own program
- Lower upfront costs
Get Pricing
Get Pricing of the Bear 150 VFD | Variable Frequency Drive